Convertizoarele de frecventa SINAMICS G120 sunt proiectate pentru a oferi un control viteza/cuplu cat mai precis si cu costuri cat mai scazute pentru motoarele trifazate.
Sunt de versiuni diverse (gabarite de la FSA la FSGX) acoperind o gama de puteri de la 0.37 kW la 250 kW, reprezentand solutii de actionare pentru o gama foarte variata de aplicatii.
6SL3200-0AE30-0AA0 | STARTERKIT SINAMICS G120C BESTEHEND AUS BASIC OPERATOR PANEL (BOP-2), SINAMICS G120C NENNLEISTUNG 0,55KW MIT 150% UEBERLAST FUER 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRIERTER FILTER KLASSE A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRIERT FELDBUS INTEGRIERT: PROFINET-PN SCHUTZART: IP20/ UL OPEN TYPE GROESSE:FSAA 173X73X178(HXBXT) EXTERNE 24V |
6SL3200-0AE40-0AA0 | STARTERKIT SINAMICS V90 PN & SIMOTICS S-1FL6 BESTEHEND AUS: SINAMICS V90 MIT PROFINET 6SL3210-5FB10-4UF1 EINGANGSSPANNUNG:1/3 AC200-240V 2.6A 0-330HZ FUER MOTOR: 0.4KW IP20, FS B, 55X170X170(BXHXT) SERVOMOTOR 1FL6034-2AF21-1AA1 PN=0.4KW, NN=3000U/MIN M0=1,27NM, MN=1,27NM ACHSHOEHE 30MM, IP65 GEBER INKREMENTAL TTL 2500INK/U MIT PASSFEDER, OHNE HALTEBREMSE LEISTUNGSLEITUNG KONFEKTIONIERT 6FX3002-5CK01-1AD0 3METER SIGNALLEITUNG KONFEKTIONIERT 6FX3002-2CT20-1AD0 3METER I/O KABEL KONFEKTIONIERT 6SL3260-4MA0 |
6SL3200-0SF01-0AA0 | SINAMICS ERSATZLUEFTER FUER POWER MODULE PM240/PM340 FSA UND FSB |
6SL3200-0SF03-0AA0 | SINAMICS ERSATZLUEFTER FUER POWER MODULE PM240/PM250/PM340 FSC |
6SL3200-0SF04-0AA0 | SINAMICS ERSATZLUEFTER FUER POWER MODULE PM240/PM250/PM340 FSD, 15KW UND 18,5KW UND FUER POWER MODULE PM240/PM250/PM340 FSE, LEISTUNG 30KW SET BESTEHEND AUS 2 LUEFTERN |
6SL3200-0SF05-0AA0 | SINAMICS ERSATZLUEFTER FUER POWER MODULE PM240/PM250/PM340 FSD, LEISTUNGEN 22KW UND FUER POWER MODULE PM240/PM250/PM340 FSE, LEISTUNG 37KW SET BESTEHEND AUS 2 LUEFTERN |
6SL3200-0SF06-0AA0 | SINAMICS ERSATZLUEFTER FUER POWER MODULE PM240/PM250/PM340 FSF, LEISTUNGEN 45KW UND 55KW SET BESTEHEND AUS 2 LUEFTERN |
6SL3200-0SF07-0AA0 | SINAMICS ERSATZLUEFTER FUER POWER MODULE PM240/PM340 FSF, LEISTUNG 75KW UND FUER POWER MODULE PM260 FSF SET BESTEHEND AUS 2 LUEFTERN |
6SL3200-0SF08-0AA0 | SINAMICS ERSATZLUEFTER FUER POWER MODULE PM250 FSF, LEISTUNG 75KW SET BESTEHEND AUS 2 LUEFTERN |
6SL3200-0SF11-0AA0 | SINAMICS ERSATZLUEFTER FUER POWER MODULE PM260 FSD |
6SL3200-0SF12-0AA0 | SINAMICS G120/G120C LUEFTEREINHEIT FSA BESTEHEND AUS EINSTECKBARE HALTERUNG MIT VORMONTIERTEM LUEFTER PASSEND FUER PM2X0-2 UND G120C |
6SL3200-0SF13-0AA0 | SINAMICS G120/G120C LUEFTEREINHEIT FSB BESTEHEND AUS EINSTECKBARE HALTERUNG MIT VORMONTIERTEM LUEFTER PASSEND FUER PM2X0-2 UND G120C |
6SL3200-0SF14-0AA0 | SINAMICS G120/G120C LUEFTEREINHEIT FSC BESTEHEND AUS EINSTECKBARE HALTERUNG MIT VORMONTIERTEM LUEFTER PASSEND FUER PM2X0-2 UND G120C |
6SL3200-0SF15-0AA0 | SINAMICS Ersatzlüfter für Power Module PM 240-2 FSD |
6SL3200-0SF16-0AA0 | SINAMICS Ersatzlüfter für Power Module PM 240-2 FSE |
6SL3200-0SF17-0AA0 | SINAMICS Ersatzlüfter für Power Module PM 240-2 FSF |
6SL3200-0SF21-0AA0 | SINAMICS G120P / G120 EXTERNE LUEFTEREINHEIT FUER PM230 IP55 / UL TYPE12 FSA UND PM2X0-2 PUSH-THROUGH FSA HARDWARE VERSION BEACHTEN! GEEIGNET FUER PM230 FSA BIS HARDWARE VERSION A03! |
6SL3200-0SF21-0AA1 | SINAMICS G120P EXTERNE LUEFTEREINHEIT FUER POWER MODULE PM230 IP55 / UL TYPE12 FSA |
6SL3200-0SF22-0AA0 | SINAMICS G120P / G120 EXTERNE LUEFTEREINHEIT FUER PM230 IP55 / UL TYPE12 FSB UND PM2X0-2 PUSH-THROUGH FSB |
6SL3200-0SF22-0AA1 | SINAMICS G120P EXTERNE LUEFTEREINHEIT FUER POWER MODULE PM230 IP55 / UL TYPE12 FSB |
6SL3200-0SF23-0AA0 | SINAMICS G120P / G120 EXTERNE LUEFTEREINHEIT FUER PM230 IP55 / UL TYPE12 FSC UND PM2X0-2 PUSH-THROUGH FSC |
6SL3200-0SF23-0AA1 | SINAMICS G120P / G120 EXTERNE LUEFTEREINHEIT FUER PM230 IP55 / UL TYPE12 FSC UND PM2X0-2 PUSH-THROUGH FSC |
6SL3200-0SF24-0AA0 | SINAMICS G120P EXTERNE LUEFTEREINHEIT FUER PM230 IP55 / UL TYPE12 FSD UND FSE |
6SL3200-0SF26-0AA0 | SINAMICS G120P EXTERNE LUEFTEREINHEIT FUER PM230 IP55 / UL TYPE12 FSF |
6SL3200-0SF31-0AA0 | SINAMICS G120P INTERNE LUEFTEREINHEIT FUER POWER MODULE PM230 IP55 / UL TYPE12 FSA, FSB, FSC |
6SL3200-0SF32-0AA0 | SINAMICS G120P INTERNE LUEFTEREINHEIT FUER POWER MODUL PM230 IP55 / UL TYPE12 FSD, FSE, FSF |
6SL3200-0SF38-0AA0 | SINAMICS G120C Dachlüfter für FSAA bestehend aus obere Geräteabdeckung mit vormontiertem Lüfter |
6SL3200-0SF40-0AA0 | SINAMICS G120C DACHLUEFTER FUER FSA BESTEHEND AUS OBERE GERAETEABDECKUNG MIT VORMONTIERTEM LUEFTER |
6SL3200-0SF41-0AA0 | SINAMICS G120C DACHLUEFTER FUER FSB BESTEHEND AUS OBERE GERAETEABDECKUNG MIT VORMONTIERTEM LUEFTER |
6SL3200-0SF42-0AA0 | SINAMICS G120C DACHLUEFTER FUER FSC BESTEHEND AUS OBERE GERAETEABDECKUNG MIT VORMONTIERTEM LUEFTER |
6SL3200-0SK01-0AA0 | SINAMICS G120 ERSATZTEILKIT FUER CONTROL UNITS CU230P-2, CU240B/E-2 UND CU250S-2 |
6SL3200-0SK02-0AA0 | SINAMICS G120P SMALL MOUNTING PARTS FOR POWER MODUL PM230 IP55 / UL TYPE12 FSA OR IP20 |
6SL3200-0SK03-0AA0 | SINAMICS G120P SMALL MOUNTING PARTS FOR POWER MODULE PM230 IP55 / UL TYPE12 FSB OR IP20 |
6SL3200-0SK04-0AA0 | SINAMICS G120P SMALL MOUNTING PARTS FOR POWER MODUL PM230 IP55 / UL TYPE12 FSC OR IP20 |
6SL3200-0SK05-0AA0 | SINAMICS G120P SMALL PARTS ASSEMBLY SET FOR POWER MODULE PM230 IP55 / UL TYPE12 FSD |
6SL3200-0SK06-0AA0 | SINAMICS G120P SMALL PARTS ASSEMBLY SET FOR POWER MODULE PM230 IP55 / UL TYPE12 FSE |
6SL3200-0SK07-0AA0 | SINAMICS G120P SMALL PARTS ASSEMBLY SET FOR POWER MODULE PM230 IP55 / UL TYPE12 FSF |
6SL3200-0SK08-0AA0 | SINAMICS Kleinteile-Montage-Set für Power Module PM 240-2 FSDEF |
6SL3200-0SK40-0AA0 | SINAMICS G120C ERSATZTEILKIT I BESTEHEND AUS 5 SETS I/O-ANSCHLUSSKLEMMEN, 1 SET KLEMMENTUEREN UND 1 STUECK PANEL-BLINDABDECKUNG |
6SL3200-0SK41-0AA0 | SINAMICS G120C ERSATZTEILKIT I BESTEHEND AUS 5 SETS I/O-ANSCHLUSSKLEMMEN, 1 SET KLEMMENTUEREN PN 1 SET KLEMMENTUEREN AND. VAR. 1 STUECK PANEL-BLINDABDECKUNG |
6SL3200-0SM10-0AA0 | SINAMICS ERSATZTUER FUER POWER MODULE PM240 FSGX |
6SL3200-0SM11-0AA0 | SINAMICS TERMINAL COVER KIT FUER POWER MODULE PM FSD, FSE |
6SL3200-0SM12-0AA0 | SINAMICS TERMINAL COVER KIT FUER POWER MODULE PM FSF |
6SL3200-0SM13-0AA0 | SINAMICS Terminal Cover Kit für Power Module PM 240-2 FSD |
6SL3200-0SM14-0AA0 | SINAMICS Terminal Cover Kit für Power Module PM 240-2 FSE |
6SL3200-0SM15-0AA0 | SINAMICS Terminal Cover Kit für Power Module PM 240-2 FSF |
6SL3200-0SP01-0AA0 | SINAMICS ERSATZTEIL CIM PM-IF FUER POWER MODULE PM240 FSGX CIB, POWER SUPPLY BOARD UND MONTAGEBLECH |
6SL3200-0SP02-0AA0 | SINAMICS ERSATZTEIL IF-IPD-KARTE FUER POWER MODULE PM240 FSGX 3AC 380-480V, 50/60HZ / 310A |
6SL3200-0SP03-0AA0 | SINAMICS ERSATZTEIL IF-IPD-KARTE FUER POWER MODULE PM240 FSGX 3AC 380-480V, 50/60HZ / 370A |
6SL3200-0SP04-0AA0 | SINAMICS ERSATZTEIL IF-IPD-KARTE FUER POWER MODULE PM240 FSGX 3AC 380-480V, 50/60HZ / 477A |
6SL3200-0ST04-0AA0 | SINAMICS ERSATZ-ANSCHLUSSSTECKER FUER POWER MODULE PM260 |
6SL3200-0ST04-0AA1 | PM260 FSD STECKER 6SL3200-0ST04-0AA1 REPAIR FOR MICROMASTER |
6SL3200-0ST05-0AA0 | SINAMICS G120/G120C ANSCHLUSSTECKER FSA BESTEHEND AUS ANSCHLUSSSTECKER FUER NETZ, MOTOR, ZWISCHENKREIS UND BREMSWIDERSTAND PASSEND FUER PM2X0-2 UND G120C |
6SL3200-0ST06-0AA0 | SINAMICS G120/G120C ANSCHLUSSTECKER FSB BESTEHEND AUS ANSCHLUSSSTECKER FUER NETZ, MOTOR, ZWISCHENKREIS UND BREMSWIDERSTAND PASSEND FUER PM2X0-2 UND G120C |
6SL3200-0ST07-0AA0 | SINAMICS G120/G120C CONNECTOR PLUGS FSC INCLUDES CONNECTOR PLUGS FOR CONNECTOR PLUGS FOR AND BRAKING RESISTOR USED FOR PM2X0-2 UND G120C |
6SL3201-0BE12-0AA0 | SINAMICS BRAKING RESISTOR FOR POWER MODULE FSB FOOT PRINT |
6SL3201-0BE14-3AA0 | SINAMICS BRAKING RESISTOR R=370OHM P_RATED=75W P_MAX=1500W/12S/5% DUTY STANDALONE |
6SL3201-0BE21-0AA0 | SINAMICS BRAKING RESISTOR R=140OHM P_RATED=200W P_MAX=4000W/12S/5% DUTY STANDALONE |
6SL3201-0BE21-8AA0 | SINAMICS BRAKING RESISTOR R=75OHM P_RATED=375W P_MAX=7500W/12S/5% DUTY STANDALONE |
6SL3201-0BE23-8AA0 | SINAMICS BRAKING RESISTOR R=30OHM P_RATED=925W P_MAX=18500W/12S/5% DUTY STANDALONE |
6SL3201-2AD20-8VA0 | SINAMICS V20 BRAKING MODULE 3AC380V-480V / 1AC200V-240V DUTY CYCLE 5% TO 100% |
6SL3202-0AE16-1CA0 | SINAMICS OUTPUT REACTOR FOR POWER MODULES FSA1 3AC 380V-480V 6,1 A |
6SL3202-0AE18-8CA0 | SINAMICS OUTPUT REACTOR FOR POWERMODULE FSA2 3AC 380V-480V 9,0 A |
6SL3202-0AE20-3SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSA FOOT PRINT 3AC 380-480V 3,5A |
6SL3202-0AE20-6SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSA FOOT PRINT 3AC 380-480V 6,0A |
6SL3202-0AE21-0CA0 | SINAMICS OUTPUT REACTOR FOR POWER MODULE FSB FOOT PRINT |
6SL3202-0AE21-1SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSB FOOT PRINT 3AC 380-480V 9,0A |
6SL3202-0AE21-4SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSB FOOT PRINT 3AC 380-480V 14,0A |
6SL3202-0AE21-8CA0 | SINAMICS OUTPUT REACTOR FOR POWERMODULE FSB 3AC 380V-480V 18,5A |
6SL3202-0AE22-0SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSC FOOT PRINT 3AC 380-480V 20,0A |
6SL3202-0AE23-3SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSC FOOT PRINT 3AC 380-480V 33,0A |
6SL3202-0AE23-8CA0 | SINAMICS OUTPUT REACTOR FOR POWERMODULE FSC 3AC 380V-480V 39 A |
6SL3202-0AE24-6SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSD STAND ALONE 3AC 380-480V 47,0A |
6SL3202-0AE26-2SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSD STAND ALONE 3AC 380-480V 61,8A |
6SL3202-0AE28-8SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSE STAND ALONE 3AC 380-480V 92,0A |
6SL3202-0AE31-5SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSF STAND ALONE 3AC 380-480V 150,0A |
6SL3202-0AE31-8SA0 | SINAMICS SINE-WAVE FILTER FOR POWER MODULE FSF STAND ALONE 3AC 380-480V 182,0A |
6SL3202-0AJ23-2CA0 | SINAMICS OUTPUT REACTOR FOR POWER MODULE FSC FOOT PRINT |
6SL3203-0BD23-8SA0 | SINAMICS SUPPL. LINE FILTER CL. B FOR POWER MODULE FSC FOOT PRINT 3AC 380-480V 39,4A 362 X 190 X 55 MM H X W X D |
6SL3203-0BE17-7BA0 | SINAMICS LINE FILTER CLASS B FOR POWER MODULE FSA FOOT PRINT 3AC 380V-480V 11,4A |
6SL3203-0BE21-6SA0 | SINAMICS SUPPL. LINE FILTER CL. B FOR POWER MODULE FSB FOOT PRINT 3AC 380-480V 10,2A 296 X 153 X 50 MM H X W X D |
6SL3203-0BE21-8BA0 | SINAMICS LINE FILTER CLASS B FOR POWER MODULE FSB FOOT PRINT 3AC 380V-480V 23,5A |
6SL3203-0BE23-8BA0 | SINAMICS LINE FILTER CLASS B FOR POWER MODULE FSC FOOT PRINT 3AC 380V-480V 49,4A |
6SL3203-0BE27-5BA0 | SINAMICS LINE FILTER CLASS B FOR POWER MODULE FSD 3AC 380V-480V 72A |
6SL3203-0BE31-1BA0 | SINAMICS LINE FILTER CLASS B FOR POWER MODULE FSE 3AC 380V-480V 105A |
6SL3203-0BE31-8BA0 | SINAMICS LINE FILTER CLASS B FOR POWER MODULE FSF 3AC 380V-480V 204A |
6SL3203-0BE32-5AA0 | SINAMICS SUPPL. LINE FILTER CL. A FOR POWER MODULE PM240 FSF FROM 110KW LO 3AC 380-480V 250A 360 X 240 X 116 MM H X W X D |
6SL3203-0CD21-0AA0 | SINAMICS LINE REACTOR FOR POWER MODULE FSB 2.2 AND 3,0 KW, FOOT PRINT |
6SL3203-0CD21-4AA0 | SINAMICS LINE REACTOR FOR POWER MODULE FSB 4.0 KW, FOOT PRINT |
6SL3203-0CD22-2AA0 | SINAMICS LINE REACTOR FOR POWER MODULE FSC 7,5 AND 11 KW RATED POWER BASED ON I_L FOOT PRINT |
6SL3203-0CD23-5AA0 | SINAMICS LINE REACTOR FOR POWER MODULE FSC 15 KW, RATED POWER BASED ON I_L FOOT PRINT |
6SL3203-0CD25-3AA0 | SINAMICS LINE REACTOR FOR POWER MODULE FSD 30 KW, RATED POWER BASED ON I_L FOOT PRINT |
6SL3203-0CE13-2AA0 | SINAMICS LINE REACTOR 380-480V 3AC 47-63HZ I_LN = 4,0A STANDALONE |
6SL3203-0CE21-0AA0 | SINAMICS LINE REACTOR 380-480V 3AC 47-63HZ I_LN = 11,3A STANDALONE |
6SL3203-0CE21-8AA0 | SINAMICS LINE REACTOR 380-480V 3AC 47-63HZ I_LN = 22,3A STANDALONE |
6SL3203-0CE23-8AA0 | SINAMICS LINE REACTOR 380-480V 3AC 47-63HZ I_LN = 47,0A STANDALONE |
6SL3203-0CJ24-5AA0 | SINAMICS LINE REACTOR FOR POWER MODULE FSD 18.5 AND 22 KW, RATED POWER BASED ON I_L FOOT PRINT |
6SL3203-0CJ28-6AA0 | SINAMICS LINE REACTOR FOR POWER MODULE FSE 37 AND 45 KW, RATED POWER BASED ON I_L FOOT PRINT |
6SL3210-1KE11-8AB1 | SINAMICS G120C RATED POWER 0,55KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE11-8AB2 | SINAMICS G120C Nennleistung 0,55kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE11-8AF1 | SINAMICS G120C RATED POWER 0,55KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE11-8AF2 | SINAMICS G120C Nennleistung 0,55kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE11-8AP1 | SINAMICS G120C RATED POWER 0,55KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE11-8AP2 | SINAMICS G120C Nennleistung 0,55kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE11-8UB1 | SINAMICS G120C RATED POWER 0,55KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-10% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE11-8UB2 | SINAMICS G120C Nennleistung: 0,55kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-10% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE11-8UF1 | SINAMICS G120C RATED POWER 0,55KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE11-8UF2 | SINAMICS G120C Nennleistung 0,55kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE11-8UP1 | SINAMICS G120C RATED POWER 0,55KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE11-8UP2 | SINAMICS G120C Nennleistung 0,55kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE12-3AB1 | SINAMICS G120C RATED POWER 0,75KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE12-3AB2 | SINAMICS G120C Nennleistung: 0,75kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE12-3AF1 | SINAMICS G120C RATED POWER 0,75KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE12-3AF2 | SINAMICS G120C Nennleistung: 0,75kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE12-3AP1 | SINAMICS G120C RATED POWER 0,75KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE12-3AP2 | SINAMICS G120C Nennleistung: 0,75kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE12-3UB1 | SINAMICS G120C RATED POWER 0,75KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE12-3UB2 | SINAMICS G120C Nennleistung: 0,75kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE12-3UF1 | SINAMICS G120C RATED POWER 0,75KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE12-3UF2 | SINAMICS G120C Nennleistung: 0,75kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE12-3UP1 | SINAMICS G120C RATED POWER 0,75KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE12-3UP2 | SINAMICS G120C Nennleistung: 0,75kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE13-2AB1 | SINAMICS G120C RATED POWER 1,1KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE13-2AB2 | SINAMICS G120C Nennleistung: 1,1kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE13-2AF1 | SINAMICS G120C RATED POWER 1,1KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE13-2AF2 | SINAMICS G120C Nennleistung: 1,1kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE13-2AP1 | SINAMICS G120C RATED POWER 1,1KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE13-2AP2 | SINAMICS G120C Nennleistung: 1,1kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE13-2UB1 | SINAMICS G120C RATED POWER 1,1KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE13-2UB2 | SINAMICS G120C Nennleistung: 1,1kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE13-2UF1 | SINAMICS G120C RATED POWER 1,1KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE13-2UF2 | SINAMICS G120C Nennleistung: 1,1kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE13-2UP1 | SINAMICS G120C RATED POWER 1,1KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE13-2UP2 | SINAMICS G120C Nennleistung: 1,1kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE14-3AB1 | SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE14-3AB2 | SINAMICS G120C Nennleistung: 1,5kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE14-3AF1 | SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE14-3AF2 | SINAMICS G120C Nennleistung: 1,5kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE14-3AP1 | SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE14-3AP2 | SINAMICS G120C Nennleistung: 1,5kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE14-3UB1 | SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE14-3UB2 | SINAMICS G120C Nennleistung: 1,5kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE14-3UF1 | SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE14-3UF2 | SINAMICS G120C Nennleistung: 1,5kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE14-3UP1 | SINAMICS G120C RATED POWER 1,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE14-3UP2 | SINAMICS G120C Nennleistung: 1,5kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE15-8AB1 | SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE15-8AB2 | SINAMICS G120C Nennleistung: 2,2kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE15-8AF1 | SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE15-8AF2 | SINAMICS G120C Nennleistung: 2,2kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE15-8AP1 | SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE15-8AP2 | SINAMICS G120C Nennleistung: 2,2kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz integrierter Filter Klasse A I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE15-8UB1 | SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE15-8UB2 | SINAMICS G120C Nennleistung: 2,2kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: USS/MODBUS Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE15-8UF1 | SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE15-8UF2 | SINAMICS G120C Nennleistung: 2,2kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFINET-PN Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 178 (HxBxT) externe 24V |
6SL3210-1KE15-8UP1 | SINAMICS G120C RATED POWER 2,2KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE15-8UP2 | SINAMICS G120C Nennleistung: 2,2kW mit 150% Überlast für 3 Sec. 3AC380-480V+10/-20% 47-63Hz ungefiltert I/O-Interface: 6DI, 2DO, 1AI, 1AO Safe-Torque-Off integriert Feldbus integriert: PROFIBUS-DP Schutzart IP20/UL Open Typ Größe: FSAA 173x 73x 155 (HxBxT) externe 24V |
6SL3210-1KE17-5AB1 | SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE17-5AF1 | SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE17-5AP1 | SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE17-5UB1 | SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE17-5UF1 | SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE17-5UP1 | SINAMICS G120C RATED POWER 3,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE18-8AB1 | SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE18-8AF1 | SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE18-8AP1 | SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE18-8UB1 | SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE18-8UF1 | SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE18-8UP1 | SINAMICS G120C RATED POWER 4,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSA 196X73X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-3AB1 | SINAMICS G120C RATED POWER 5,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-3AF1 | SINAMICS G120C RATED POWER 5,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-3AP1 | SINAMICS G120C RATED POWER 5,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-3UB1 | SINAMICS G120C RATED POWER 5,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-3UF1 | SINAMICS G120C RATED POWER 5,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-3UP1 | SINAMICS G120C RATED POWER 5,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-7AB1 | SINAMICS G120C RATED POWER 7,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-7AF1 | SINAMICS G120C RATED POWER 7,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-7AP1 | SINAMICS G120C RATED POWER 7,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-7UB1 | SINAMICS G120C RATED POWER 7,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-7UF1 | SINAMICS G120C RATED POWER 7,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE21-7UP1 | SINAMICS G120C RATED POWER 7,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSB 196X100X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE22-6AB1 | SINAMICS G120C RATED POWER 11,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE22-6AF1 | SINAMICS G120C RATED POWER 11,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE22-6AP1 | SINAMICS G120C RATED POWER 11,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE22-6UB1 | SINAMICS G120C RATED POWER 11,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE22-6UF1 | SINAMICS G120C RATED POWER 11,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE22-6UP1 | SINAMICS G120C RATED POWER 11,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-2AB1 | SINAMICS G120C RATED POWER 15,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-2AF1 | SINAMICS G120C RATED POWER 15,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-2AP1 | SINAMICS G120C RATED POWER 15,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-2UB1 | SINAMICS G120C RATED POWER 15,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-2UF1 | SINAMICS G120C RATED POWER 15,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-2UP1 | SINAMICS G120C RATED POWER 15,0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-8AB1 | SINAMICS G120C RATED POWER 18,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-8AF1 | SINAMICS G120C RATED POWER 18,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-8AP1 | SINAMICS G120C RATED POWER 18,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-8UB1 | SINAMICS G120C RATED POWER 18,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-8UF1 | SINAMICS G120C RATED POWER 18,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1KE23-8UP1 | SINAMICS G120C RATED POWER 18,5KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ UNFILTERED I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFIBUS-DP PROTECTION: IP20/ UL OPEN TYPE SIZE: FSC 295X140X203(HXWXD) EXTERNAL 24V |
6SL3210-1NE11-3AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 0,37kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE11-3AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE11-3AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE11-3UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 0,37kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE11-3UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE11-3UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,37KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE11-7AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 0,55kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE11-7AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE11-7AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE11-7UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 0,55kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE11-7UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE11-7UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE12-2AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter; Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 0,75kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE12-2AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE12-2AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE12-2UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 0,75kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE12-2UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE12-2UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0,75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE13-1AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter; Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 1,1kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE13-1AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,1KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE13-1AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,1KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE13-1UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 1,1kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE13-1UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,1KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE13-1UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,1KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE14-1AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 1,5kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE14-1AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE14-1AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE14-1UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 1,5kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE14-1UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE14-1UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE15-8AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 2,2kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE15-8AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 2,2KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE15-8AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 2,2KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE15-8UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 2,2kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE15-8UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 2,2KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE15-8UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 2,2KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE17-7AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 3kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE17-7AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 3KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE17-7AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 3KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE17-7UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 3kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 196x 73x 165 (HxBxT), FSA ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE17-7UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 3KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE17-7UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 3KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD), FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-0AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 4kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 292x 100x 165 (HxBxT), FSB ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE21-0AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-0AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-0UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 4kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 292x 100x 165 (HxBxT), FSB ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE21-0UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-0UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-3AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 5,5kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 292x 100x 165 (HxBxT), FSB ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE21-3AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 5,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-3AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 5,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-3UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 5,5kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 292x 100x 165 (HxBxT), FSB ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE21-3UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 5,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-3UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 5,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-8AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 7,5kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 292x 100x 165 (HxBxT), FSB ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE21-8AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-8AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-8UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 7,5kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 292x 100x 165 (HxBxT), FSB ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE21-8UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE21-8UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD), FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE22-6AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 11kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 355x 140x 165 (HxBxT), FSC ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE22-6AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 11KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE22-6AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 11KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE22-6UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 11kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 355x 140x 165 (HxBxT), FSC ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE22-6UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 11KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE22-6UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 11KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE23-2AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 15kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 355x 140x 165 (HxBxT), FSC ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE23-2AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE23-2AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE23-2UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 15kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 355x 140x 165 (HxBxT), FSC ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE23-2UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE23-2UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE23-8AG1 | SINAMICS G120 Power Module PM 230 mit integriertem Klasse-A-Filter Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 18,5kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 355x 140x 165 (HxBxT), FSC ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE23-8AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE23-8AL1 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE23-8UG1 | SINAMICS G120 Power Module PM 230 ungefiltert Schutzart IP20 3AC380-480V+10/-10% 47-63Hz Leistung low overload: 18,5kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur 0 bis +40°C (LO) 355x 140x 165 (HxBxT), FSC ohne Control Unit und Bedieneinheit freigegeben für CU240B/E-2 und CU230P-2 ab Firmware-Version V4.4 |
6SL3210-1NE23-8UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE23-8UL1 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 18,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 355 X 140 X 165 (HXWXD), FSC WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE24-5AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 22KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 419 X 275 X 204 (HXWXD), FSD WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE24-5UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 22KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 419 X 275 X 204 (HXWXD), FSD WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE26-0AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 30KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 419 X 275 X 204 (HXWXD), FSD WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE26-0UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 30KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 419 X 275 X 204 (HXWXD), FSD WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE27-5AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 37KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 419 X 275 X 204 (HXWXD), FSD WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE27-5UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 37KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 419 X 275 X 204 (HXWXD), FSD WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE28-8AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 45KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 499 X 275 X 204 (HXWXD), FSE WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE28-8UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 45KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 499 X 275 X 204 (HXWXD), FSE WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE31-1AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 55KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 499 X 275 X 204 (HXWXD), FSE WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE31-1UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 55KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 499 X 275 X 204 (HXWXD), FSE WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE31-5AL0 | SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 75KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 634 X 350 X 316 (HXWXD), FSF WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1NE31-5UL0 | SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 75KW FOR 110% 60S,100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 634 X 350 X 316 (HXWXD), FSF WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY |
6SL3210-1PB13-0AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0,55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB13-0UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0,55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB13-8AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0,75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB13-8UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0,75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB15-5AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,1KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB15-5UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,1KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB17-4AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,1KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB17-4UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,1KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB21-0AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 2,2KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB21-0UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 2,2KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB21-4AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 3KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB21-4UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 3KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB21-8AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 3KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PB21-8UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 3KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PC22-2AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 4KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 5,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PC22-2UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 4KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 5,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PC22-8AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 5,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PC22-8UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 5,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PC24-2UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC200-240V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 7,5KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 11KW BEI 150% 3S,110% 57S,10 |
6SL3210-1PC25-4UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC200-240V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 11KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 15KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PC26-8UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC200-240V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 15KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 18,5KW BEI 150% 3S,110% 57S,1 |
6SL3210-1PC28-0UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC200-240V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 18,5KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 22KW BEI 150% 3S,110% 57S,1 |
6SL3210-1PC31-1UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC200-240V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 22KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 30KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PC31-3UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC200-240V+10/-20% 47-63Hz Leistung hohe Überlast: 30kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 37kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PC31-6UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC200-240V+10/-20% 47-63Hz Leistung hohe Überlast: 37kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 45kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PC31-8UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC200-240V+10/-20% 47-63Hz Leistung hohe Überlast: 45kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 55kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PE11-8AL1 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0,55KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE11-8UL1 | SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,37KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0,55KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE12-3AL1 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0,75KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE12-3UL1 | SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0,75KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE13-2AL1 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,1KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE13-2UL1 | SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,1KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE14-3AL1 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,1KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,5KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE14-3UL1 | SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,1KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1,5KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE16-1AL1 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 2,2KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE16-1UL1 | SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 2,2KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE18-0AL1 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 3KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE18-0UL1 | SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 3KW AT 150% 3S,110% 57S,100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE-VERSION V4.6 |
6SL3210-1PE21-1AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 3KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE21-1UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 3KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE21-4AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 4KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 5,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE21-4UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 4KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 5,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE21-8AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 5,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE21-8UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 5,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 7,5KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD), FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE22-7AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 11KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE22-7UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 7,5KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 11KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE23-3AL0 | SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE23-3UL0 | SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 355 X 140 X 165 (HXWXD), FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR FIRMWARE- VERSION V4.6 |
6SL3210-1PE23-8AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 15KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 18,5KW BEI |
6SL3210-1PE23-8UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 15KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 18,5KW BEI 150% 3S,110% 57S,1 |
6SL3210-1PE24-5AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 18,5KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 22KW BEI |
6SL3210-1PE24-5UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 18,5KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 22KW BEI 150% 3S,110% 57S,1 |
6SL3210-1PE26-0AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 22KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 30KW BEI 15 |
6SL3210-1PE26-0UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 22KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 30KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PE27-5AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 30KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 37KW BEI 15 |
6SL3210-1PE27-5UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 30KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 37KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PE28-8AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 37KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 45KW BEI 15 |
6SL3210-1PE28-8UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 37KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 45KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PE31-1AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 45KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 55KW BEI 15 |
6SL3210-1PE31-1UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC380-480V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 45KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 55KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PE31-5AL0 | SINAMICS G120 Power Module PM 240-2 mit integriertem Klasse-A-Filter mit integriertem Brems-Chopper 3AC380-480V+10/-20% 47-63Hz Leistung hohe Überlast: 55kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 75kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PE31-5UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC380-480V+10/-20% 47-63Hz Leistung hohe Überlast: 55kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 75kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PE31-8AL0 | SINAMICS G120 Power Module PM 240-2 mit integriertem Klasse-A-Filter mit integriertem Brems-Chopper 3AC380-480V+10/-20% 47-63Hz Leistung hohe Überlast: 75kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 90kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PE31-8UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC380-480V+10/-20% 47-63Hz Leistung hohe Überlast: 75kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 90kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PE32-1AL0 | SINAMICS G120 Power Module PM 240-2 mit integriertem Klasse-A-Filter mit integriertem Brems-Chopper 3AC380-480V+10/-20% 47-63Hz Leistung hohe Überlast: 90kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 110kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PE32-1UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC380-480V+10/-20% 47-63Hz Leistung hohe Überlast: 90kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 110kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PE32-5AL0 | SINAMICS G120 Power Module PM 240-2 mit integriertem Klasse-A-Filter mit integriertem Brems-Chopper 3AC380-480V+10/-20% 47-63Hz Leistung hohe Überlast: 110kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 132kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PE32-5UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC380-480V+10/-20% 47-63Hz Leistung hohe Überlast: 110kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 132kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PH21-4AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 7,5KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 11KW BEI 1 |
6SL3210-1PH21-4UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 7,5KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 11KW BEI 150% 3S,110% 57S,10 |
6SL3210-1PH22-0AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 11KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 15KW BEI 15 |
6SL3210-1PH22-0UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 11KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 15KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PH22-3AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 15KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 18,5KW BEI |
6SL3210-1PH22-3UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 15KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 18,5KW BEI 150% 3S,110% 57S,1 |
6SL3210-1PH22-7AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 18,5KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 22KW BEI |
6SL3210-1PH22-7UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 18,5KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 22KW BEI 150% 3S,110% 57S,1 |
6SL3210-1PH23-5AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 22KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 30KW BEI 15 |
6SL3210-1PH23-5UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 22KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 30KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PH24-2AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 30KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 37KW BEI 15 |
6SL3210-1PH24-2UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 30KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 37KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PH25-2AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 37KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 45KW BEI 15 |
6SL3210-1PH25-2UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 37KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 45KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PH26-2AL0 | SINAMICS G120 POWER MODULE PM240-2 MIT INTEGRIERTEM FILTER KL. A MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 45KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 55KW BEI 15 |
6SL3210-1PH26-2UL0 | SINAMICS G120 POWER MODULE PM240-2 UNGEFILTERT MIT INTEGRIERTEM BREMSCHOPPER 3AC500-690V +10/-20% 47-63HZ LEIST. HOHE UEBERLAST: 45KW BEI 200% 3S,150% 57S,100% 240S UMGEBUNGSTEM. -20 BIS +50 GRD C (HO) LEIST. GERI. UEBERLAST: 55KW BEI 150% 3S,110% 57S,100 |
6SL3210-1PH28-0AL0 | SINAMICS G120 Power Module PM 240-2 mit integriertem Klasse-A-Filter mit integriertem Brems-Chopper 3AC500-690V+10/-20% 47-63Hz Leistung hohe Überlast: 55kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 75kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PH28-0UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC500-690V+10/-20% 47-63Hz Leistung hohe Überlast: 55kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 75kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PH31-0AL0 | SINAMICS G120 Power Module PM 240-2 mit integriertem Klasse-A-Filter mit integriertem Brems-Chopper 3AC500-690V+10/-20% 47-63Hz Leistung hohe Überlast: 75kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 90kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PH31-0UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC500-690V+10/-20% 47-63Hz Leistung hohe Überlast: 75kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 90kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PH31-2AL0 | SINAMICS G120 Power Module PM 240-2 mit integriertem Klasse-A-Filter mit integriertem Brems-Chopper 3AC500-690V+10/-20% 47-63Hz Leistung hohe Überlast: 90kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO), Leistung geringe Überlast: 110kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PH31-2UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC500-690V+10/-20% 47-63Hz Leistung hohe Überlast: 90kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 110kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PH31-4AL0 | SINAMICS G120 Power Module PM 240-2 mit integriertem Klasse-A-Filter mit integriertem Brems-Chopper 3AC500-690V+10/-20% 47-63Hz Leistung hohe Überlast: 110kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO), Leistung geringe Überlast: 132kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
6SL3210-1PH31-4UL0 | SINAMICS G120 Power Module PM 240-2 ungefiltert mit integriertem Brems-Chopper 3AC500-690V+10/-20% 47-63Hz Leistung hohe Überlast: 110kW bei 200% 3S, 150% 57S, 100% 240S; Umgebungstemperatur -20 bis +50°C (HO); Leistung geringe Überlast: 132kW bei 150% 3S, 110% 57S, 100% 240S; Umgebungstemperatur -20 bis +40°C (LO) 708x 305x 357 (HxBxT), FSF Schutzart IP20 ohne Control Unit und Bedieneinheit freigegeben ab CU Firmware- Version V4.7 HF8 |
Prin continuarea navigării pe website-ul nostru confirmati acceptarea utilizării fișierelor de tip cookie conform Politicii de Cookie . Nu uitati totuși că poteti modifica setările acestor fișiere cookie urmând instrucțiunile din Politica de Cookie. Politica de Cookie
The cookie settings on this website are set to "allow cookies" to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click "Accept" below then you are consenting to this.